OPT-Professional Machine Vision Lighting Provider

Product search:
Your current location: Home > Products > Controller

OPT-APA0405F-4 Current analog controller for spot Light


Download

Manual:

OPT-APA0405F-4 manual.zip

Drawing:

OPT-APA0405F-4.PDF

DEMO & SDK

DEMO & SDK.zip

Model No.


Order code

Channel

Matching lights

OPT-APA0405F-1

1

0.4A / 5V lights

OPT-APA0405F-2

2

0.4A / 5V lights

OPT-APA0405F-3

3

0.4A / 5V lights

OPT-APA0405F-4

4

0.4A / 5V lights


Product Features

1. Manual stepless intensity control

2. Trigger signal input: connect an external signal source (e.g. a camera trigger signal) for synchronized strobing of the illumination device.

3. Easy to install: screw and DIN rail mounting available

Device Overview

No.

Interface

Description

1

Intensity adjustment

One key per channel

2

TS Trigger switch key

To switch between "ON" and "OFF" trigger mode

3

AC power input

100 - 240 V AC, 50/60 Hz

4

Ground

Ground protection

5

Trigger connector

For connection with an external trigger source such as a PLC, sensor or camera

6

Light connector

For 0.4 A / 5 V spot lights

7

Power

To turn the controller on/off

Remark:

The drawing of APA0405F-4 as below.

The quantity of intensity adjust keys, external trigger connectors and Light connectors of APA0405F-1/2/3 are 1, 2,3 respectively.


Connection Setup

Step 1: Turn the intensity adjustment key to zero (counterclockwise)

Step 2: Connect the light with the controller; pls. refer to the drawing above

Step 3: For external triggering, connect the external trigger source with the trigger port.

Step 4: Connect the controller with a 100 - 240 V AC power source and switch the controller on. The indicator is lit.

Step 5: Turn the intensity adjustment key until the intended brightness of the light is reached.

Parameter Description

Item 

Parameter 


Description

Output current

0~0.4A

the change of current is stepless

Intensity control

stepless

Manual control via intensity adjust

key, the intensity change is stepless

External trigger

Synchronized strobe with external trigger signal


Trigger mode

ON / OFF

NPN trigger is ok

Trigger delay time

≤80μs


External trigger frequency

1KHz Max.


Trigger control

On/Off switch

Pressing the TS switch to change the

mode between ON and OFF

Output power

2W/CH  


Input voltage

100 - 240 V AC, 50/60HZ


Standby power consumption

APA0405F-1 

<3.5W

Tested at 220 V AC

APA0405F-2 

<3.6W

APA0405F-3 

<4.0W

APA0405F-4 

<4.5W

Hi-Pot test

1500 V AC, max.1 minute

Leak current < 10 mA

Insulation resistance

500 V DC

Insulation resist >20 MΩ

Working temp.

-5℃~50℃


Size(MM)

73.5*129.5*166


Weight (KG)

APA0405F-1/2  

0.65±0.02


APA0405F-3/4  

0.70±0.02


Trigger port and setup

APA0405F-1/2/3/4 has 1, 2, 3, or 4 channels seperately; each channel has two pins, “+” and “-“. 

Please find the details about the wiring scheme of the trigger ports for the APA0405F-4 below.

Anolog controller has ON and OFF two trigger modes which can be set inside the controller.

Please refer to the chart below to choose the best mode for your application.

TS

Trigger mode

Description

Up

ON

Tirg+ and Trig- port disconnected, the light is on;

Trig+ and Trig- port connected, the light is off.

Down

OFF

Tirg+ and Trig- port disconnected, the light off;

Trig+ and Trig- port connected, the light is on.

Sequence Diagram

◆ ON mode

When the COM port connect the external signal, 

the lighting is on when "trigger+" and "trigger-" port disconnected (high level trigger), 

the lighting is off when "trigger+“ and "trigger -" port connected (low level trigger).

◆ OFF mode

When the COM port connect the external signal, 

the lighting is off when "trigger+" and "trigger-" port disconnected (high level trigger),

the lighting is on when "trigger+"and "trigger -" disconnected (low level trigger).

Wiring Scheme of Switch and Trigger Port

Dimensions [mm]