OPT-Professional Machine Vision Lighting Provider

Product search:
Your current location: Home > Products > Controller

OPT-DPA6024-2 High power current digital controller


Download

Drawing: 

OPT-DPA6024-2-V2.0.zip

Model No.


Product Features

1. 256 intensity levels

2. Short circuit protection

3. Trigger signal input: connect an external signal source (e.g. a camera trigger signal) for synchronized strobing of the illumination device

4. Configuration via PC: The intensity and triggering of the light can be controlled via RS232 interface. We offer corresponding software to help you integrate

    the illumination into your system.

5. Manual control of the intensity directly at the controller.

6. The controller settings are stored within the device, even when switched off.

Device Overview

NO.

Item

Description

1

Company logo

OPT brand

2

Power

Turns the controller on/off

3

4-digit display

The first number indicates the channel and the other 3 numbers

show related data

4

Indicator

Shows the status of the channel, ON means active, OFF means

inactive.

5

Operating key

S: Set/check button, +: plus, -: minus

6

Light connector

For the connection with OPT line lights

7

Trigger connector

For connection with an external trigger source such as a PLC,

sensor or camera

8

AC power input

100 - 120 V AC or 200 - 240 V AC

9

PE:Ground

Ground protection

10

Fan

For cooling

11

Serial port, female

For the connection with PC

Step 1: Refer to drawing above to connect the light with the controller.

Step 2: For external triggering, connect the external trigger source with the trigger port

Step 3: Connect the controller with a 100 -120V AC or 200 - 240V AC power source and switch the controller on. The digital display is lit. 

            If the intensity of the light shall be controlled via PC, you need to connect the PC with an RS232 cable or Ethernet cable before the

            controller is switched on. Use the provided software or your own application to communicate with the controller. You can adjust the

            settings via the PC or manually.

Connector specification

Pin

Pin Definition

1

Light+

2

Light-

3

Fan+

4

Fan-

5

Res

6

Res

Parameter Description

 Item

 Parameter

 Instruction

Rated power

5A, 24V

For 24V line Light

Intensity control

256 levels 

Adjust by the intensity adjust key or

DEMO software

Trigger mode

Switch trigger

Supports NPN output

External trigger  input

Synchronous strobe with  external signal


Short cricuit protection 

Yes

Be started when output is short circuit

Trigger delay time

≤100μs


External trigger frequency

1KHz Max


Channel

2


RS232

Baud rate:9600BPS

For parameter setting and control

of the device

Output power 

144W per channel, 288W per 2 channels

Total power output < 300 W

Input Voltage

Input AC100-120v or AC200〜240V

Can be changed by internal switch

Overvoltage resistance

1500VAC, max. 1 min

Leak current < 1mA

Insulation resistance

500VDC

>20 MΩ

Standby power consumption

<11W


Size (mm)

136 x 326 x 104.5


Weight(kg)

2.1



Trigger Port

DPA6024- 2 has two trigger channels, each channel has a “+” and “-“ pin. See the wiring diagram below for details.

Trigger Mode Setup

This digital controller has two modes, “ON” and “OFF”. See the table below for details.


Output mode

Description

ON

Trig+ is high and Trig- is zero: the light is ON. Short circuit of Trig + and

Trig-: the light is OFF

OFF

Trig+ is high and Trig- is zero: the light is OFF. Short circuit of Trig+ and

Trig-: the light is ON

Remark: 0 - 1 V is low-power, 5 - 24 V is high-power.


Sequence Diagram

◆ ON mode

When connect with external signal, Trig+ and Trig- are off which is high voltage and Light is ON; 

To do short circuit to Trig+ and Trigwhich is lower voltage and Light is OFF.

◆ OFF mode

When connect with an external signal, Trig+ and Trig- are off which is high voltage and Light is OFF; 

To do short circuit to Trig+ and Trig- which is lower voltage and Light is ON.


Wiring Scheme of Switch and Trigger Port


Dimensions [mm]