OPT-Professional Machine Vision Lighting Provider

Product search:
Your current location: Home > Products > Controller



OPT-APA6024-2 High Power Analog Controller


Download

Drawing:

OPT-APA3024-2-V1.0.zip

OPT-APA6024-2-V1.0.zip

Model No.


NO.

P/N

Channel

Matching lights

1

APA6024-2

2

0.8 - 6 A line lights

2

APA3024-2

2

0.8 - 3 A line lights


Product Features

1. Continuous control of the current strength

2. Short circuit protection

3. Trigger signal input: connect an external signal source (e.g. a camera trigger signal) for synchronized strobing of the illumination device.

4. Detects max. output current automatically

Device Overview

No.

Item

Description

1

Company logo

OPT brand

2

Power

Turns the controller on/off

3

Intensity adjustment

Adjusts the intensity and width of the trigger pulse

4

Light connector

For 24 V line lights

5

AC power input

Input voltage 100-120 or 200 - 240 V AC, 50/60 Hz

6

Trigger connector

For connection with an external trigger source such as a PLC, sensor or camera

7

Ground

Ground protection

8

Fan

For cooling of the device

Connection Setup

Step 1: Turn the intensity adjustment wheels to zero (counterclockwise)

Step 2: Connect the light with the controller; pls. refer to the drawing above

Step 3: For external triggering, connect the external trigger source with the trigger port.

Step 4: Connect the controller with a 100 - 120VAC or 200-240VAC power source and switch the controller on. The indicator is lit.

Step 5: Turn the intensity adjustment wheels until the intended brightness of the light is reached.

Connector specification:

Pin

Pin Definition

1

Light+

2

Light-

3

Fan+

4

Fan-

5

Res

6

Res

Parameter Description

 Item

 Parameter

 Instruction

Input voltage

 100 - 120 V A C or 200 - 240 V A C

Change by internal switch

Intensity control

 continuous

Manually at the device

Trigger mode

 Switch

Supports NPN trigger

Trigger delay time

 ≤100μs


External trigger input

Light strobing is synchronized with external trigger


External trigger 

frequency

1KHz Max


Channel

2CH


Output power

APA3024-2

72W per channel


144W per 2 channel


APA6024-2

144W per channel


288W per 2 channel


Voltage withstand

1500 V AC, max. 1 minute

Leak current <10 mA

Insulation resistance

500 V DC

Insulation resistance >20 MΩ

Working temp

-5-50℃


Standby power 

consumption

≤11W


Size(MM)

APA3024-2

136*270.5*104.5


APA6024-2

136*305.8*104.5


Weight (KG)

APA3024-2

1.8


APA6024-2

2.1


Trigger port

Please refer to the drawing of the trigger port of APA6024-2 below regarding the wiring scheme.

Trigger Mode Setup

This digital controller has two modes, “ON” and “OFF”, which can be set internally. 

Please refer to the chart below to choose the best mode for your application.

Trigger mode

Description

Continuous on

Tirg+ and Trig- port is disconnected, the light is continuous on;

Trig+ and Trig- port is connected, the light is turned off.

Turn off

Tirg+ and Trig- port is disconnected, the light is turned off;

Trig+ and Trig- port is connected, the light is continuous on.

Sequence Diagram

◆ Continuous on mode

When the COM port connect the outside signal, 

the lighting is continuous on if the input signal of "trigger+" and "trigger-" port disconnected (high voltage trigger), 

the lighting is turned off if the input signal of "trigger+“ and "trigger -" is connected (lower voltage trigger).

◆ Turn off mode

When the COM port connect the outside signal, 

the lighting is turned off if the input signal of "trigger+" and "trigger-" port disconnected (high voltage trigger), 

the lighting is continuous on if the input signal of "trigger+“ and "trigger -" is disconnected (lower voltage trigger).


Wiring Scheme of Switch and Trigger Port



Dimensions [mm]