OPT-Professional Machine Vision Lighting Provider

Product search:
Your current location: Home > Products > Controller

OPT-AP1024F-4 Voltage analog controller


Download

Manual: 

OPT-AP1024F-4.zip

Drawing:

OPT-AP1024F-4.zip

Model No.


Model

Channel

Light

OPT-AP1024F-1

1

for 10mA - 1A 24 V lights

OPT-AP1024F-2

2

for 10mA - 1A 24 V lights

OPT-AP1024F-3

3

for 10mA - 1A 24 V lights

OPT-AP1024F-4

4

for 10mA - 1A 24 V lights


Product Features

1. Continuous intensity control, gradeless

2. Trigger signal input: connect an external signal source (e.g. a camera trigger signal) for synchronized strobing of the illumination device. 

    Width of the trigger pulse can be defined.

3. Easy to install: screw mount or DIN rail are available

Device Overview

No.

Item

Description

1

Intensity adjustment

One key per channel

2

TS Trigger switch key

Switches the triggering on or off

3

AC power input

Input voltage 100 - 240 V AC, 50/60 Hz

4

Ground

Ground protection

5

Trigger connector

For connection with an external trigger source such as a PLC, sensor or camera

6

Light connector

For 24 V lights, < 1A

7

Power

Turns the controller on/off

Remark: 

Specification also widely valid for AP1024F-4 Number of connectors and light connectors of AP1024F-1/2/3 are 1, 2, or 3 respectively.

Connection Setup

Step 1: Turn the intensity adjustment wheels to zero (counterclockwise).

Step 2: Connect the light with the controller; pls. refer to the drawing above.

Step 3: For external triggering, connect the external trigger source with the trigger port.

Step 4: Connect the controller with a 100 - 240 V AC power source and switch the controller on. The indicator is lit.

Step 5: Turn the intensity adjustment key until the intended brightness of the light is reached. 

Parameter Descripition

Items

Parameter

Description

Output voltage

14.0~24.0V(±0.2V)

Allows for continuous voltage adjustment

Intensity control

continuous

Munual adjust key

Internal trigger

Synchronous strobe with external signal


Trigger mode

Switch trigger

Supports NPN trigger

Trigger delay time

≤80 μs


External trigger

frequency

1KHz Max


Trigger control

On/Off switch

To change the mode between ON and OFF 

through pressing the TS switch

Output power

20 W per channel

Total output power of AP1024F-1/2< 30 W

Total output power of AP1024F- 3/4< 40 W

Power

100 - 240 V AC 50/60 Hz

Input ordinary voltage

Standby power

consumption

AP1024F-1

<3.5W

Tested at 220 V AC

AP1024F-2

<3.6W

AP1024F-3

<4.5W

AP1024F-4

<5.0W

Overvoltage resistance

1500 V AC, max. 1 minute

Leak current < 10 mA

Insulation resistance

500 V DC

>20 MΩ

Working temp.

-5°C - 50°C


Size(mm)

73.5*129.5*166


Weight [kg]

AP1024F-1/2

0.6±0.02


AP1024F-3/4

0.7±0.02






























Trigger Port and Setup

AP1024F-1/2/3/4 offer 1, 2, 3, or 4 channels respectively, each channel has a “+” and “-“ input port. See the drawing of the trigger port of AP1024F-4

below. Please refer to the connection scheme for detail.

TS

Trigger mode

Description

Up

Continuous on

Tirg+ and Trig- port is disconnected, the light is continuous on;

Trig+ and Trig- port is connected, the light is turned off.

Down

Turn off

Tirg+ and Trig- port is disconnected, the light is turned off;

Trig+ and Trig- port is connected, the light is continuous on.

Sequence Diagram

◆ Continuous on mode

When the COM port connect the outside signal, 

the lighting is continuous on if the input signal of "trigger+" and "trigger-" port disconnected (high voltage trigger), 

the lighting is turned off if the input signal of "trigger+“ and "trigger -" is connected (lower voltage trigger).

◆ Turn off mode

When the COM port connect the outside signal, 

the lighting is turned off if the input signal of "trigger+" and "trigger-" port disconnected (high voltage trigger), 

the lighting is continuous on if the input signal of "trigger+“ and "trigger -" is disconnected (lower voltage trigger).

Wiring Scheme of Switch and Trigger Port

Dimensions [mm]